This note describes the changes included in RealFLO Version 6.75.1 released on August 17, 2010.

RealFLO 6.74.4 (build 1285) replaced with version 6.75.1 (build 1342)

  • RealFLO file version is 6.75.1342
  • Flow computer version is 6.75.6

New Features Introduced in RealFLO 6.75.1

  • Licensing for ProductionPLUS

Improvements Made in RealFLO 6.75.1

  • Update Reading should not read transmitter configuration every time
  • Maintenance Mode Open File Dialog Windows are not large enough to view file names if they are several folders deep
  • Improve operator interaction with secured flow computer
  • Synchronize Accounts with Flow Computer when Admin user opens Accounts dialog
  • Export transmitter upper/low range limits to calibration report file for Rosemount calibration
  • Synchronize RealFLO/Flow Computer account settings
  • The default folder should not point to Program Files folder
  • Windows 7 Support
  • Report current or forced value of input in PEMEX Modbus
  • PEMEX Gas Quality stream

Corrections Made in RealFLO 6.75.1

  • FC does not return sensor polling to the OS when application is stopped
  • Inconsistent Force Inputs behavior in RealFLO.
  • Calculations not stopped when changing the 'Values on Sensor Fail' field.
  • Transmitter configuration should be read back even if there is not any run use them
  • Tree toolbar and menu are inconsistent after turning on Update Reading
  • AGA-3 1992 volume not calculated from fixed relative density
  • Flow Computer Configuration Corruption on 10th Run
  • PEMEX up time measurement is incorrect
  • Flow Time is not reset when a new day record is created due to a change in AGA-8 settings
  • An Event is not created when source of gas quality input is changed on the Pemex Flow Computer
  • When opening a new file and reading from flow computer with security, real flow won't let me do it
  • After creating a new file, I am still logged on as Administrator and I am able to do anything to the flow computer without logging on
  • After creating a new file by reading from the flow computer, the actual log on level is not shown correctly
  • If a new file is created by a Read Only User and then closed, the user cannot log on again if they reopen the file
  • After creating a new file, I got a no name is defined error when reading the logs
  • Account dialog includes password and PIN entries
  • Up Time accumulates across intermediate days, but when the contract day ended it did not get reset
  • Don't write Mapping table setting in PEMEX mode if user is logged on as read/write
  • An error message popped up when open IP configuration dialog
  • Up Time is not accumulating properly
  • Must Prevent Changes to Modbus Mapping when user is logged on at Read/Write level
  • Up Time not accumulating correctly in hourly history log
  • Compressibility Calculation control should be removed from Flow calculations step in new file wizard
  • Tap Location controls are enabled in new file wizard step by step page, but disabled in Run configuration dialog.
  • Calibration wizard does not execute Force Value for diff pressure in GOST mode.
  • The Read button is disabled in the Add/Edit Sensor Settings dialog for a Read user.
  • There is not any information shows up for difference comparison of Run configurations
  • Calibration report file doesn't include differential pressure description in GOST mode
  • PEMEX Up Time accumulation
  • AGA-8 Configuration Screen shows 'Laboratory' in the actual column instead of 'Manual' when source is set to 'Manual'
  • Text is misleading on the configuration wizard for Flow Run Identification
  • Copy will cause RealFLO to crash.
  • Calibration report may include confused information
  • ProductionPLUS controller options are blocked for some Neptune controllers
  • Read only user not able to view current configuration in Maintenance Mode
  • The status bar didn't update when create a new file in offline after opened an existing file.
  • The error message need to update
  • Protocol field should be disabled when Port field is not LAN
  • Too many error message dialogs
  • PEMEX Gas Quality Register Order
  • PEMEX Daily Report is missing the most recent record