Please read the information below prior to upgrading to ClearSCADA 2007 R1 for important information on changes in this version and any known issues.

  • Business Objects have released Crystal Reports XI Developer Edition Release 2. This version is compatible with ClearSCADA 2007 R1. If you wish to edit any report, you MUST use Crystal Reports XI Release 2. This is available as a free upgrade to Crystal Reports XI Release 1 from the Business Objects website for those customers owning Crystal Reports XI Release 1. You cannot use Release 1 to edit reports in ClearSCADA 2007 R1.
  • Context-sensitive help will not work when the ClearSCADA 2007 R1 server is emulating a previous version.
  • User favorites cannot be exported from ClearSCADA 2007 R1 to previous versions due to a change in format to support the new super favourites feature.
  • Previous versions of ClearSCADA would allow logic programs and scripts to modify properties of objects in template instances even if the property override on that property would not normally allow the change. This would then result in template instance database integrity errors. In ClearSCADA 2007 R1, the product has been modified such that logic programs and scripts can only change these properties if the property override allows it. This may mean that programs that worked in earlier builds will not work correctly in this version. Property overrides will need to be modified to allow the programs to continue to work properly once this new version is installed.
  • The way system commands are executed has changed in ClearSCADA 2007 R1. When upgrading to this release, you must configure the username and password for system commands in the server config tool otherwise the system commands will not run.
  • Due to changes for Windows Vista, the configuration files for ViewX have changed location. See ClearSCADA 2007 R1 Changes To File Locations for specific details. This means that previously where only 1 file had to be managed per machine now multiple files need to be managed and new logon sessions catered for. For example if a standard "ViewX Global Settings.dat" is used on machines and is copied by administrators to all machines to ensure consistency then now multiple files need to be copied to multiple user directories. When a new user is created then the file needs to also exist in the "Default User" (if Vista works that way) so when the new user gets a copy of the directory they also get the correct settings files.
  • Due to the changes in file locations, there can be problems if you downgrade from ClearSCADA 2007 R1 to ClearSCADA 2007 R0. In ClearSCADA 2007 R0 and earlier versions, the path lengths are restricted to 64 characters, this is not the case in ClearSCADA 2007 R1. When a server is downgraded, the file locations can get truncated, resulting in the server not running correctly. It is recommended that on a downgrade that the file locations are manually checked to ensure that they are shorter than the 64 character limit and altered as necessary.
  • ClearSCADA 2007 R0 contained a bug, where it allowed mimic parameters to contain special characters. Mimic parameters containing special characters are inaccessible to client side scripts. ClearSCADA 2007 R1 has been fixed to disallow special characters in mimic parameters, ensuring that any parameter created by a user can be accessed by a script.
  • Registry settings for client application are now stored in HKEY_CURRENT_USER instead of HKEY_LOCAL_MACHINE. The main settings affected by this are the ViewX & DBClient log file settings, and the ViewX/Mimics key used by mimic animations & pick actions. These settings will be reset to defaults on an upgrade.
  • On Windows Vista, the following programs require Administrator rights and will give a UAC prompt when run interactively:
    • DBServer
    • All drivers
    • ClearSCADA Client (Control Panel)
    • Service Manager
    • AE Printer
    • Licence Server
    • Port Server
    • Demo
  • All other programs (ViewX, Server Icon, Server Status, Server Config, SCXCmd) all run as a standard user. Note that attempting to start DBServer from the system tray icon will give a UAC prompt.
  • On a clean install on Windows Vista, ViewX will not be able to create a default system when it is first run, unless it is run as Administrator. In this case, or if there is no server running on the local machine, the ClearSCADA Client control panel applet will be displayed.
  • Similar to issues with logic and scripts being allowed to write to non-overridden properties in template instances, previous versions of ClearSCADA would allow the Flow Run objects configuration to be read even if the property overrides on the Flow Run would not normally allow this. In ClearSCADA 2007 R1, the product has been modified such that a 'Read Configuration' may only be executed if the property override allows it. This may mean that Flow Run objects that were able to perform a 'Read Configuration in earlier builds will not work correctly in this version. Property overrides will need to be modified to allow the 'Read Configuration to continue to work properly once this new version is installed. Currently if the upload fails due to fields not having property overrides enabled, then up to 3 event journal messages will be logged. One for general flow run configuration fields that could not be updated, one for compressibility calculation fields that could not be updated and one for flow calculation fields that could not be updated. These event journal messages will indicate which specific fields in those areas that do not have property overrides.  It should also be noted that if the uploaded field does not have a property override and the value is the same as the database it will not be reported as a failure.  The fields that need to have property override enabled on them are as listed below (all items with 'Yes' written in the 'Uploaded' column).

Flow Run Object Fields

Name Uploaded
AlarmLogScanInterval No
AlarmLogScanOffset No
AlarmLogSeverity No
AllowAutoReadOfConfig No
AreaOfInterest No
AreaOfInterestId No
Confirm No
ContractBasePressure Yes
ContractBaseTemp Yes
ContractHour Yes
ContractUnits Yes
ContractWetGasMeterFact Yes
CurrentScanInterval No
CurrentScanOffset No
DailyHistScanInterval No
DailyHistScanOffset No
EventLogScanInterval No
EventLogScanOffset No
EventLogSeverity No
FlowRunConfigScanInt No
FlowRunConfigScanOffset No
FlowRunId Yes
FlowRunNumber No
HourlyHistScanInterval No
HourlyHistScanOffset No
HysteresisUnits Yes
InputUnits Yes
InService No
LowFlowEvents Yes
OutstationId No
ReadConfigAtStartup No
Severity No
Source No
SourceName No
StaticPresAltitude Yes
StaticPresAtmospheric Yes
StaticPresInputReg Yes
StaticPresInputType Yes
StaticPresLatitude Yes
StaticPresLocation Yes
StaticPressureType Yes
StaticPresTapLocation Yes
StatPresEngAtFullScale Yes
StatPresEngAtZeroScale Yes
StatPresRawAtFullScale Yes
StatPresRawAtZeroScale Yes
TempEngAtFullScale Yes
TempEngAtZeroScale Yes
TempInputReg Yes
TempInputType Yes
TempRawAtFullScale Yes
TempRawAtZeroScale Yes

AGA8 Fields

Name Uploaded
Argon Yes
CarbonDioxide Yes
CarbonMonoxide Yes
CompositionUnits No
ConfigurationEvents Yes
EthaneC2H6 Yes
HeatingValue Yes
Helium Yes
HexanesPlus Yes
HexanesPlusnDecane Yes
HexanesPlusnHeptane Yes
HexanesPlusnHexane Yes
HexanesPlusnNonane Yes
HexanesPlusnOctane Yes
HexanesPlusRatios Yes
Hydrogen Yes
HydrogenSulfide Yes
iButane Yes
iPentane Yes
MethaneCH4 Yes
nButane Yes
nDecane Yes
nHeptane Yes
nHexane Yes
Nitrogen Yes
nNonane Yes
nOctane Yes
nPentane Yes
Oxygen Yes
PropaneC3H8 Yes
RelativeDensity Yes
Source Yes
Water Yes

NX-19 Fields

Name Uploaded
CarbonDioxide Yes
ConfigurationEvents Yes
HeatingValue Yes
Nitrogen Yes
SpecificGravity Yes

AGA-3 (1985 & 1992)

Name Uploaded
BetaRatio Sort of. This is calculated from orifice and pipe diameter fields. Field is read only.
ChamberType Yes
DiffPressureDeadband Yes
IsentropicExponent Yes
OrificeDiameter Yes
OrificeMaterial Yes
OrificeMeasurementTemp Yes
PipeDiameter Yes
PipeMaterial Yes
PipeMeasurementTemp Yes
StaticPressureDeadband Yes
TemperatureDeadband Yes
Viscosity Yes

AGA-7

Name Uploaded
KFactor Yes
LowFlowDetectTime Yes
LowFlowPulseLimit Yes
MFactor Yes
TurbineInputRegister Yes
TurbineInputType Yes

V-Cone

Name Uploaded
Coefficient1 Yes
Coefficient10 Yes
Coefficient2 Yes
Coefficient3 Yes
Coefficient4 Yes
Coefficient5 Yes
Coefficient6 Yes
Coefficient7 Yes
Coefficient8 Yes
Coefficient9 Yes
ConeDiameter Yes
ConeMaterial Yes
ConeMeasurementTemp Yes
FlowCoefficents Yes
IsentropicExponent Yes
PipeInsideDiameter Yes
PipeMaterial Yes
PipeMeasurementTemp Yes
ReynoldsNumber1 Yes
ReynoldsNumber10 Yes
ReynoldsNumber2 Yes
ReynoldsNumber3 Yes
ReynoldsNumber4 Yes
ReynoldsNumber5 Yes
ReynoldsNumber6 Yes
ReynoldsNumber7 Yes
ReynoldsNumber8 Yes
ReynoldsNumber9 Yes
Viscosity Yes